Diagnostic Error Code FRU/Action
018-197-XXX
PCI Card test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
018-198-XXX
PCI Card test aborted
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Flash the system and re-test. See “Flash
update procedures” on page 111
3. Go to “Undetermined problems” on page
78
018-199-XXX
PCI Card test failed, cause unknown
1. Go to “Undetermined problems” on page
78
2. Flash the system and re-test. See “Flash
update procedures” on page 111
3. Replace component under function test
018-250-XXX
PCI Card Services error
1. PCI card
2. Riser card, if installed
3. System board
020-000-XXX
PCI Interface Test Passed
No action
020-0XX-XXX
PCI Interface error
1. PCI card
2. Riser card, if installed
3. System board
020-195-XXX
PCI Test aborted by user
Information only
Re-start the test, if necessary
020-196-XXX
PCI test halt, error threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
020-197-XXX
PCI test warning
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
64 Lenovo E200 Hardware Maintenance Manual